2-Stage Air to Water High Temperature Heat Pump
2-Stage Air to Water High Temperature Heat Pump
2-Stage Air to Water High Temperature Heat Pump
2-Stage Air to Water High Temperature Heat Pump

2-Stage Air to Water High Temperature Heat Pump

  • (R32 or R410a) + (R134a or R515b)
  • EVI inverter technology
  • 2-stage heating system technology
  • Can work under – 35C ambient
  • Function: 80℃~ 90℃ Hot Water ouse Heating / Domestic Hot Water, Water Disinfection
  • High COP, saves energy and safety
  • High-performance technology under low ambient temperature
  • Smart Defrost Technology
  • Multi-Protection, Long Service Life
  • High-efficiency EEV control
  • High Efficient FANTASTIC customize heat exchanger
  • Special design for anti-freezing and anti-frosting in the bottom of air exchanger

Applications:

  • House heating, Old house with radiator and replacing old gas heater or electric heater
  • Apartment, Vilas, Hotel
  • Hospital or workshop special using
  • Dairy farm, electric plating factory
  • Food disinfection, drying, laundry, and so on
INQUIRY
  • Description
  • More Information
  • Video

2-Stage Air to Water High Temperature Heat Pump Core Strengths

75℃ ~ 85 ℃ hot water –  Fantastic air source 2-stage high-temperature heat pump is combining the R410A/R32 system + R134A/R515b refrigerant system. R410A/R32 system provides good working conditions to R134A/R515b system and with Fantastic patent control logic, R134a can make 75℃ ~ 80 ℃ hot water, and RR515b can make 90℃ hot water.

Work under -35℃ ambient – it’s the best solution for a heat pump in cold areas, our high temperature can provide stable enough heating capacity and high water temperature even if the outdoor temperature is -35℃.

2-Stage Air to Water High Temperature Heat Pump Core Strengths

Stable 75~80℃/90℃ Hot Water

Thanks to Fantastic unique 2-stage heating technology (R410A/R32 system + R134a/R515b system), Fantastic high-temperature heat pump can make hot water up to 75~80℃(90℃ by R515b). It’s good and popular for the old house with radiators that need high-temperature hot water to replace the old gas heater or electric heater. And it’s also available for other industrial and agricultural uses.

Stable 75~80℃/90℃ Hot Water

Stable 75 °C ~ 85°C with DC Inverter Technology

Stable 75 °C ~ 85°C with DC Inverter Technology

Safe and Stable Operation Under -35℃ Ambient Temperature

Thanks to the 2-stage system, Fantastic high-temperature heat pump has a wide working ambient temperature range: of -35℃~43℃, which makes the unit available in any weather to meet the demands of summer cooling, winter heating and hot water throughout the year.

Safe and Stable Operation Under -35℃ Ambient Temperature

Smart Defrost Technology

Intelligent defrost technology to reduce the defrosting times and thus extend the unit heating time. Rapid defrosting to shorten defrost time can help to recover supply water temperature quickly, improve the unit heating efficiency and maintain comfort.

Smart Defrost Technology

Fantastic Spiral Type High Efficient Heat Exchanger

Fantastic spiral type highly efficient heat exchanger with increased heat exchanger area to improve the heat transfer ability and evenly distribute over the surface of the copper, reducing water film, and improving efficiency.

Fantastic Spiral Type High Efficient Heat Exchanger

Special Design for Anti-freezing and Anti-frosting in the Bottom of the Air Exchanger

With a 2-layer separate design, the top layer is for the fan and evaporator, the bottom layer is for the compressor and heat exchanger, and block up slopes on 2 sides of the button + anti-freezing element on the top layer + the use of special liquid distribution technology. When the unit is working in heating mode, the temperature of the refrigerant in the air exchanger’s bottom copper tube will not decrease in order to ensure no frosting on it and smooth drainage.

Special Design for Anti-freezing and Anti-frosting in the Bottom of the Air Exchanger

 

Model FEIHHD030S FEIHHD060S3 FEIHHD120T3 FEIHHD150T3 FEIHHD250T3 FEIHHD300T3
Max Water Oulet Temp. 80℃ 80℃ 80℃ 80℃ 80℃ 80℃
Power supply V/P/Hz 220/1/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Inverter Heating Performance Range
Heating capacity kW 2.9~17.0 5.8~30.0 11.5~58.0 14.5~72.0 24.0~120.0 35.0-142.5
COP range W/W 1.5~16.0 1.5~16.0 1.5~16.0 1.5~16.0 1.5~16.0 1.5~16.0
Heating Condition : Ambient 20℃ Water outlet 80℃
Heating capacity kW 14.0 28.0 56.0 70.0 115.0 140.0
Power input kW 5.75 11.50 23.00 29.00 47.70 57.50
COP 2.43 2.43 2.43 2.41 2.41 2.43
Heating Condition : Ambient 7℃ Water outlet 80℃
Heating capacity kW 12.9 26.3 52.6 65.2 108.5 130.3
Power input kW 5.5 11.20 22.30 27.90 46.30 56.00
COP 2.35 2.35 2.36 2.34 2.34 2.33
Heating Condition : Ambient -12℃ Water outlet 80℃
Heating capacity kW 10 20 40.5 47.2 81.0 101.0
Power input kW 5.1 10.2 20.50 25.30 42.50 51.00
COP 1.96 1.96 1.98 1.87 1.91 1.98
Heating Condition : Ambient -20℃ Water outlet 80℃
Heating capacity kW 8.8 17.7 35.8 41.8 71.7 89.4
Power input kW 5.2 10.4 20.80 26.00 43.00 51.50
COP 1.70 1.70 1.72 1.61 1.67 1.74
Maximum power input kW 7.425 15.5 29.7 34.7 56.7 70.2
Maximum current input A 33.75 28.8 55.0 60.0 105.1 130.1
Maximum water outlet temperature 80 80 80 80 80 80
Rated water flow volume m³/h 2.322 4.64 9.29 10.63 18.58 23.22
Rated water pressure drop kPa 35 43 55 60 82 85
Water connections (external threaded) inch 1″ 1″ 1-1/4″ 1-1/2″ 2-1/2″ 2-1/2″
Refrigerant R32/R410a+R134A R32/R410a+R134A R32/R410a+R134A R32/R410a+R134A R32/R410a+R134A R32/R410a+R134A
Sound level dB(A) 56 58 60 60 68 68
Waterproof level IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Electric shock protecting grade I I I I I I
Model FEIHH030S2 FEIHH060S32 FEIHH120T32 FEIHH150T32 FEIHH250T32 FEIHH300T32
Max Water Oulet Temp. 90℃ 90℃ 90℃ 90℃ 90℃ 90℃
Power supply V/P/Hz 220/1/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Ambient 20℃,Water outlet 80℃
Heating capacity kW 13.5 27.0 54.0 67.5 112.5 135.0
Power input kW 5.75 11.50 23.00 29.00 47.70 57.50
COP / 2.35 2.35 2.35 2.33 2.36 2.35
Ambient 7℃,Water outlet 80℃
Heating capacity kW 12.5 25.0 50.0 62.5 104.2 125.0
Power input kW 5.50 11.20 22.30 27.90 46.30 56.00
COP / 2.27 2.23 2.24 2.24 2.25 2.23
Ambient -12℃,Water outlet 80℃
Heating capacity kW 9.2 18.5 37.0 46.0 76.5 92.0
Power input kW 5.1 10.2 20.50 25.30 42.50 51.00
COP / 1.80 1.81 1.80 1.82 1.80 1.80
Ambient -20℃,Water outlet 80℃
Heating capacity kW 8.1 16.2 32.5 40.5 67.5 81.0
Power input kW 5.2 10.4 20.80 26.00 43.00 51.50
COP / 1.56 1.56 1.56 1.56 1.57 1.57
Maximum power input kW 6.5 13.0 26.0 32.5 54.0 65.0
Maximum current input A 29.4 24.1 48.2 60.2 100.1 120.4
Maximum water outlet temperature 85~90 85~90 85~90 85~90 85~90 85~90
Rated water flow volume m³/h 2.12 4.30 8.60 10.75 17.92 21.50
Rated water pressure drop kPa 40 43 55 60 82 85
Water connections (external threaded) inch 1″ 1″ 1-1/4″ 1-1/2″ 2-1/2″ 3″
Refrigerant R32+R515B R32+R515B R32+R515B R32+R515B R32+R515B R32+R515B
Sound level dB(A) 53 56 60 62 68 70
Waterproof level IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Electric shock protecting grade I I I I I I

Contact Us

    Inquiry