R32 / R410A DC Inverter Swimming Pool Heat Pump
R32 / R410A DC Inverter Swimming Pool Heat Pump
R32 / R410A DC Inverter Swimming Pool Heat Pump

R32 / R410A DC Inverter Swimming Pool Heat Pump

  • R32 or R410a
  • Full-Inverter technology
  • High COP up to 15.0
  • Flexible operation mode: Powerful-smart-Silent
  • 50% speed up heating time
  • Super Silent to ≤ 43 dB (A)
  • Super speed deforsting
  • Auto Pool Heating / Cooling switch
  • Round touch controller
  • Spiral titanium heat exchanger
  • Anti-rust ABS casing
  • Down to -5℃ operation
  • Wifi Smartphone APP control remotely (Optional)
  • EEV technology
  • Automatic defrost by cycle reversal
  • Twisted titanium heat exchanger
  • Soft starter
INQUIRY
  • Description
  • More Information
  • Video

R32 / R410a DC Inverter Swimming Pool Heat Pump Core Strengths

R32 / R410a DC Inverter Swimming Pool Heat Pump Core Strengths

20 Years Experience

Fantastic company has manufactured and OEM sold over 98,000 pool heat pumps worldwide.

Certified UL from TUV for the North American market and CE for the European Market

High Efficiency of Step-Less DC inverter

As the high COP of FANTASTIC® inverter pool heat pump by this 3-core full inverter technology (inverter control, inverter compressor, DC fan motor), it’s 70% higher COP than Normal On/Off Heat Pump, 50% higher COP than Normal Inverter Heat Pump.

10 Times Quieter

Fantastic swimming pool inverter pool heat pump provides a good swimming environment, and your neighbors will love it, too!

Long Life to 12~15 Years by Good Quality Components

FANTASTIC® pool inverter heat pump heats your pool rain or shine, and using spiral titanium heat exchanger, the casing can be galvanized metal or stainless steel for option, golden fin air heat exchanger, EEV, soft start, and so on.

Built-in Wifi Control for Option

You could control your pool anytime, anywhere easily by phone.

Work Under -15

Fantastic inverter swimming pool heat pump can work at low ambient temperatures, even at -15℃ can still provide inverter pool heating. This results in less heat in colder months and maximizes your swimming season.

Heating 40℃ Water for Option

Fantastic inverter swimming pool heat pump can set the water temperature to 40℃for Spa or other applications if customers require it.

50% Faster in Heating

Once the heat pump is on, Fantastic Inverter unit can quickly pick and choose the best compressor and fan motor operating frequencies and the heat pump EEV opening automatically according to the heating or cooling demand by smart inverter control technology for the first time heating, FANTASTIC inverter heat pump can save 50% heating time than traditional heat pump on first heating.

R32 / R410a DC Inverter Swimming Pool Heat Pump Core Strengths

Inverter Plus by Full Inverter Technology

Thanks for FANTASTIC patented smart inverter technology and full inverter components on twin-rotary inverter compressor and DC brushless fan motor, Fantastic heat pump have 3 flexible operation modes: Powerful-Smart-Silent for your selection of comfortable and suitable frequency speed.

Inverter Plus by Full Inverter Technology

COP up to 16.1

Thanks to Fantastic patented smart inverter control technology, 1kw input brings up to 16kw output. When maintaining pool temperature in most of the pool season, the Inverter pool heat pump runs at a low speed which leads to the best energy-saving performance and most silent pool environment. It’s more than double the energy saving compared with a traditional On / Off heat pump.

COP up to 16.1

Wifi Smartphone App Control

Fantastic inverter pool heat pump has a Wi-Fi Remote control, which means you can control and know the working situation of your inverter pool heat pump on your Smartphone at any time and anywhere, even if you are away from home.

Wifi Smartphone App Control

Super Silent Operation

Fantastic DC Inverter swimming pool heat pump adopts a step-less inverter compressor, step-less inverter control system and brushless fan motor. By smart conversion of compressor speed, fan motor speed and system pressure, it can not only provide an amazing energy-saving effect but also silence as low as a fridge, 12dB (A) lower than a traditional On / Off heat pump.

Super Silent Operation

R32 Refrigerant for Option

R32 Refrigerant for Option

50% Speed up Heating Time

Once the heat pump is on, Fantastic Inverter unit can quickly pick and choose the best compressor and fan motor operating frequencies and the heat pump EEV opens automatically according to the heating or cooling demand by smart inverter control technology for the first-time heating, inverter fast heating can save 50% heating time than the traditional heat pump.

50% Speed up Heating Time

FIP7S FIP10S FIP13S FIP17S FIP21S FIP30S FIP35S FIP35S3
Power Supply 220~240V / 1/ 50 Hz 220~240V / 1/ 50 Hz 220~240V / 1/ 50 Hz 220~240V / 1/ 50 Hz 220~240V / 1/ 50 Hz 220~240V / 1/ 50 Hz 220~240V / 1/ 50 Hz 380V / 3/ 50 Hz
Heating Capacity Air 26℃, Humidity 80%, Water 26℃ in, 28℃ out
Heating Capacity (kW) 7.82~1.65 10.58~2.42 13.66~3.14 17.16~3.91 21.42~4.86 30.05~6.83 35.80~8.24 35.80~8.24
Power Input (kW) 1.12~0.103 1.519~0.149 1.98~0.193 2.48~0.245 3.07~0.30 4.30~0.42 5.10~0.51 5.10~0.51
COP 16.02~6.98 16.24~6.97 16.27~6.99 15.96~6.99 15.96~6.98 16.26~6.99 16.54~6.98 16.54~6.98
Heating Capacity Air 15℃, Humidity 70%, Water 26℃ in, 28℃ out
Heating Capacity (kW) 5.78~1.31 7.86~1.80 10.14~2.31 12.8~3.91 15.92~3.61 22.05~5.00 28.61~6.60 28.61~6.60
Power Input (kW) 1.15~0.17 1.57~0.236 2.03~0.30 2.56~0.38 3.19~0.47 4.42~0.65 5.73~0.87 5.73~0.87
COP 7.70~5.02 7.62~5.00 7.7~5.00 7.65~5.00 7.68~4.99 7.69~4.99 7.67~4.98 7.67~4.98
Cooling Capacity Air 35℃,  Water 29℃ in, 27℃ out
Cooling Capacity (kW) 4.30~1.08 5.94~1.50 7.26~1.85 9.49~2.38 11.60~2.96 15.88~3.92 20.13~4.67 20.13~4.67
Power Input (kW) 1.14~0.16 1.57~0.22 1.89~0.265 2.51~0.345 3.06~0.43 4.19~0.56 5.27~0.67 5.27~0.67
EER 6.75~3.77 6.82~3.78 6.98~3.84 6.90~3.78 6.93~3.79 6.99~3.79 6.99~3.81 6.99~3.81
Rated Power Input (kW) 1.2 1.6 2.1 2.6 3.2 4.4 5.7 5.7
Rated Current (A) 5.4 7.3 9.4 11.7 14.6 20.1 26 15
Refrigerant R32 R32 R32 R32 R32 R32 R32 R32
Heat Exchanger Titanium Titanium Titanium Titanium Titanium Titanium Titanium Titanium
Air Flow Direction Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal
Water Flow Volume (m3/h) 2.5 3.5 4.5 5.5 6.5 9 12 12
Kind of Defrost by 4-way valve
Working Temperature Range (℃) -15~43 -15~43 -15~43 -15~43 -15~43 -15~43 -15~43 -15~43
Noise Level (dBa) at 1m <36~<45 <37~<46 <39~<47 <40~<48 <41~<49 <42~<50 <42~<50 <42~<50
Noise Level (dBa) at 10m <19~<26 <20~<26 <20~<28 <21~<30 <23~<31 <24~<33 <24~<33 <24~<33
Casing Material ABS plastic ABS plastic ABS plastic ABS plastic ABS plastic ABS plastic ABS plastic ABS plastic
Water Proof Level IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Model FIP40T3 FIP55T3 FIP65T3 FIP80T3 FIP110T3 FIP135T3 FIP160T3 FIP270T3 FIP320T3
Power Supply 380-415V~/3Ph~50Hz (60HZ) 380-415V~/3Ph~50Hz (60HZ) 380-415V~/3Ph~50Hz (60HZ) 380-415V~/3Ph~50Hz 380-415V~/3Ph~50Hz 380-415V~/3Ph~50Hz 380-415V~/3Ph~50Hz 380-415V~/3Ph~50Hz 380-415V~/3Ph~50Hz
Operating Air Temperature (℃) -15~55 -15~55 -15~55 -15~55 -15~55 -15~55 -15~55 -15~55 -15~55
Heating Capacity Air 27℃, Water 26℃, Humidity 80%
Boost Mode Capacity (kW) 40 55 65 80 110 135 160 270 320
Heating Capacity (kW) 6.3~40 8.4~55 10.5~65 12.6~80 16.8~110 21~135 25.2~160 42~270 50.4~320
Consumed Power (kW) 0.39~6.5 0.52~8.94 0.65~10.56 0.78~13.61 1.04~17.88 1.3~21.95 1.56~26.01 2.6~43.9 3.14~52.03
COP 6.15~16.11 6.15~16.11 6.15~16.11 6.15~16.11 6.15~16.11 6.15~16.11 6.15~16.11 6.15~16.11 6.15~16.11
Heating Capacity Air 15℃, Water 26℃, Humidity 70%
Boost Mode Capacity (kW) 30 40 50 60 80 100 120 200 240
Heating Capacity (kW) 4.81~30 6.41~40 8.02~50 9.62~60 12.84~80 16.05~100 19.2~120 32.1~200 51.36~240
Consumed Power (kW) 0.96~2.96 1.27~3.95 1.59~4.93 1.91~5.92 2.59~16.16 3.24~20.2 3.87~24.24 6.48~40.4 10.37~48.48
COP 4.95~8.45 4.95~8.45 4.95~8.45 4.95~8.45 4.95~8.45 4.95~8.45 4.95~8.45 4.95~8.45 4.95~8.45
Cooling Capacity Air 43℃, Water 26℃, Humidity 70%
Boost Mode Capacity (kW) 21 28 35 42 56 70 84 140 168
Cooling Capacity(kW) 7.63~15.12 10.17~20.15 12.72~25.19 15.26~30.23 20.36~56 25.5~70 30.5~84 50.9~140 61~168
Consumed Power(kW) 1.46~3.68 1.95~4.91 2.43~6.13 2.92~7.36 3.93~13.49 4.93~16.86 5.89~20.24 9.84~33.73 11.7~40.48
EER 4.15~5.13 4.15~5.13 4.15~5.13 4.15~5.13 4.15~5.13 4.15~5.13 4.15~5.13 4.15~5.13 4.15~5.13
Casing Type Metal sheet
Compressor DC Inverter Type
Fan Direction Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical Vertical
Sound Pressure 1m dB(A) 55 58 58 60 65 68 68 70 72
Water Flow Volume (m3/h) 14 17 21 25 33 41.25 49.5 82.5 99
Refrigerant Gas R410A R410A R410A R410A R410A R410A R410A R410A R410A