2-Stage Compressor High Temperature Air to Water Heat Pump
2-Stage Compressor High Temperature Air to Water Heat Pump
2-Stage Compressor High Temperature Air to Water Heat Pump
2-Stage Compressor High Temperature Air to Water Heat Pump

2-Stage Compressor High Temperature Air to Water Heat Pump

  • R32 or R410a +R134a
  • 2-stage heating system technology
  • EVI + DC Inverter technology
  • Can work under – 35C ambient
  • Function: 85℃  Hot Water, House Heating / Domestic Hot Water, Water Disinfection
  • High COP, saves energy and safety
  • WIFI control by phone anywhere
  • Smart Defrost Technology
  • Multi-Protection, Long Service Life
  • High-efficiency EEV control
  • High Efficient FANTASTIC customize heat exchanger
  • Special design for anti-freezing and anti-frosting in the bottom of air exchanger

Applications:

  • House heating, old house with radiator and replacing old gas heater or electric heater
  • Apartment, Vilas, Hotel
  • Hospital or workshop special using
  • Dairy farm, electric plating factory
  • Food disinfection, drying, laundry, and so on
INQUIRY
  • Description
  • More Information
  • Video

2-Stage Compressor High-Temperature Air-to-Water Heat Pump Core Strengths

The best solution for high-temperature hot water and heating demand by Fantastic EVI inverter 2-Stage high-temperature heat pump.

Fantastic air source  2-stage high-temperature heat pump combines an R32 / R410A  system + R134A refrigerant system. R410a system provides good working conditions to R134a system and with Fantastic patent control logic, it can make  75℃ ~ 85 ℃ hot water.

Besides, it’s the best solution for a heat pump in a cold area, our high temperature can provide stable enough heating capacity and high water temperature even if the outdoor temperature is -35℃.

We can control our heat pump by phone with a wifi control function.

Using high efficient scroll compressor, patented highly efficient shell and tube heat exchanger, plate heat exchanger, internally threaded copper pipe hydrophilic aluminum foil evaporator with 20% larger heat exchange area than a traditional unit, large-diameter fan with large air volume, and low noise vertical air outlet design.

30% higher heating efficiency than traditional heat pump units under low temperature, stable and reliable operation with low noise.

Applying technical grade linear electronic expansion valve to control the refrigerant flow of both stages to ensure highly efficient refrigerant flow adjustments under different ambient temperatures and water temperatures for stable and reliable operation. At the same time, to eradicate the weakness of poor linear adjustment of the mechanical expansion valve and easy refrigerant leakage.

Its COP is high and much energy energy-saving (more than 70% power conservation) than other heating ways such as traditional electric boilers.

2-Stage Compressor High-Temperature Air-to-Water Heat Pump Core Strengths

Fantastic Unique 2-stage Design

Thanks to Fantastic unique 2-stage heating technology ( R32 / R410A system + R134a system), Fantastic high-temperature heat pump can make hot water up to 75~80℃. It’s good and popular for the old house with radiators that need high-temperature hot water to replace the old gas heater or electric heater. And it’s also available for other industrial and agricultural uses.

Fantastic Unique 2-stage Design

Stable 75 °C ~ 85°C with DC Inverter Technology

Stable 75 °C ~ 85°C with DC Inverter Technology

Stable Operation Under -35℃ Ambient Temperature

Thanks to the 2-stage system, Fantastic high-temperature heat pump has a wide working ambient temperature range: of -35℃~43℃, which makes the unit available in any weather to meet the demands of summer cooling, winter heating and hot water throughout the year.

Stable Operation Under -35℃ Ambient Temperature

Wifi Control By Phone

Fantastic Inverter high temp. heat pump equipped wifi control function which more convenient for you to control and adjust your heat pump by phone anytime & anywhere.

Wifi Control By Phone

Smart Defrost Technology

Intelligent defrost technology to reduce the defrosting times and thus extend the unit heating time. Rapid defrosting to shorten defrost time can help to recover supply water temperature quickly, improve the unit heating efficiency and maintain comfort.

Smart Defrost Technology

Spiral Type High Efficient Heat Exchanger

Fantastic spiral type highly efficient heat exchanger with an increased heat exchanger area to improve the heat transfer ability and evenly distribute over the surface of the copper, reducing water film, and improving efficiency.

Spiral Type High Efficient Heat Exchanger

Special Design for Anti-freezing and Anti-frosting in the Bottom of the Air Exchanger

With a 2-layer separate design, the top layer is for the fan and evaporator, the bottom layer is for the compressor and heat exchanger, and block up slopes on 2 sides of the button + anti-freezing element on the top layer + the use of special liquid distribution technology. When the unit is working in heating mode, the temperature of the refrigerant in the air exchanger’s bottom copper tube will not decrease to ensure no frosting on it and smooth drainage.

Special Design for Anti-freezing and Anti-frosting in the Bottom of the Air Exchanger

Model   FHHD030S FHHD050S FHHD050S3 FHHD060S3 FHHD100S3 FHHD120S3 FHHD150S3 FHHD250S3
Rated water output L/h 275 459 459 550 917 1101 1376 2201
Heating Condition: air DB 20℃/WB 15℃, water inlet: 60℃, water outlet: 65℃
Heating capactiy① KW 14.4 24.0 24.0 28.8 48.0 57.6 72.0 115.2
COP①A20/W60/65 W/W 2.60 2.60 2.60 2.60 2.60 2.60 2.60 2.60
Input power① KW 5.54 9.23 9.23 11.08 18.46 22.15 27.69 44.31
Input current① A 25.2 42.0 17.5 21.0 35.1 42.1 52.6 84.2
Heating condition: air DB 7℃/WB 6℃, water inlet: 60℃, water outlet: 65℃
Heating capacity② KW 11.4 19.0 19.0 22.8 38.0 46.0 57.0 95.0
COP②A7/W60/65 W/W 2.40 2.40 2.40 2.40 2.40 2.40 2.40 2.40
Input power② KW 4.75 7.92 7.92 9.50 15.83 19.17 23.75 39.58
Input current② A 21.6 36.0 15.0 18.0 30.1 36.4 45.1 75.2
Heating condition: air -7℃, water inlet: 60℃, water outlet: 65℃
Heating capacity③ KW 9.6 16.0 16.0 19.2 32.0 38.4 48.0 80.0
COP③A-7/W60/65 W/W 2.25 2.25 2.25 2.25 2.25 2.25 2.25 2.25
Input power③ KW 4.27 7.11 7.11 8.53 14.22 17.07 21.33 35.56
Input current③ A 19.4 32.3 13.5 16.2 27.0 32.4 40.5 67.5
Heating condition: air -12℃, water inlet: 60℃, water outlet: 65℃
Heating capacity④ KW 8.55 14.3 14.3 17.1 28.5 34.1 42.8 71.3
COP④   A-12/W60/65 W/W 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05
Input power④ KW 4.17 6.95 6.95 8.34 13.90 16.63 20.85 34.76
Input power④ A 19.0 31.6 13.2 15.8 26.4 31.6 39.6 66.0
Power supply V/PH/Hz 220/1/50 220/1/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50
Max running current A 37.8 62.9 26.3 31.6 52.6 63.1 78.9 126.2
Max  water outlet temperature 80
Noise dB(A) 54 54 54 54 58 58 58 58
Water flow volume m³/h 1.96 3.27 3.27 3.92 6.53 7.91 9.80 16.34
Refrigerant R410A+R134a
Working ambient temperature range -35℃~43℃

Contact Us

    Inquiry