Water to Water Ground Source Heat Pump
Water to Water Ground Source Heat Pump
Water to Water Ground Source Heat Pump
Water to Water Ground Source Heat Pump

Water to Water Ground Source Heat Pump

  • R32 or R410a
  • 3.5 kW to 300 kW or bigger
  • Function: Hot Water / Cold water/heating/cooling
  • Centralized Control
  • Copland / Danfoss Compressor
  • Electric expansion valve
  • High Efficient heat exchanger or tube in Shell heat exchanger
  • Customized Design as customer projects

Applications:

  • Residential and commercial hot water, heating/cooling: House, Apartment, Vila, Hotel, Hospital, Spa, Holiday Center, and so on
INQUIRY
  • Description
  • More Information
  • Video

Water to Water Ground Source Heat Pump Core Strengths

18 years experience – Fantastic company has manufactured over 35,000 water-to-water heat pumps worldwide.

Affordability – Save energy & high performance – As the high COP of Fantastic geothermal heat pump, it can heat the water for about 30% of the cost of heating with gas and  75% of electric water heater, High COP means more energy saving.

Ex. $ 1 input – $ 4.6 of energy output at COP of 4.6.

Long life with famous brand high-quality components – CAREL controller and CAREL expansion valve for option, Copland or Panasonic compressor, SWEP plate heat exchanger, WILO water pump, and so on. All the heat pumps are equipped with famous international brand components, and we also can manufacture the casing with stainless steel, and much experience with titanium heat exchanger heat pumps for someplace where water quality is pool or water requirement is special.

Wide models range – we can design and make from resident to commercial ground source heat pumps up to 350 kW or bigger as your actual pool situation.

Water to Water Ground Source Heat Pump Core Strengths

Wide Heating Capacity Range

The heating capacity of Fantastic water to water heat pump is up to 500kW and larger. Suitable for different sizes of project demands, no matter for household or commercial use. Customized design for different customers’ projects.

Wide Heating Capacity Range

Lower Running Cost Than Traditional Heat Pump

Fantastic heat pump has precise energy stage settings to ensure the working unit achieves the desired energy-saving efficiency. The heat pump will change the compressor using quantity according to the real heat required by the water inlet temperature. When it requires a higher heating load, the unit will use full compressor quantity; when the water temperature is close to the target set temperature and requires a lower heating load, the unit will turn off some compressors and just use the compressor quantity according to the real heat load.

Lower Running Cost Than Traditional Heat Pump

High Efficient System Design With Titanium or Copper Heat Exchanger for Option

The outside of the titanium or copper tube is screw twisted fin tube design, compared with a normal smooth copper tube, greatly increase the heat exchange area between the refrigerant and water, ensure that the refrigerant and water can fully heat exchange. There is no water flow blind zone in the water passage, the water flow velocity is uniform, and the heater is not easy to partially freeze, not easy to scale.

High Efficient System Design With Titanium or Copper Heat Exchanger for Option

High COP

Fantastic water to water heat pump has high energy saving performance, which make COP as high as 5.4.

High COP

Super-heat Management

Fantastic heat pump increases the heating capacity and extends the operating life by TEV, and increases COP and limits the discharge temperature under safe level by EEV, and lower the defrosting time to make heat pump put more time on heating and more energy-saving.

Super-heat Management

Model   FWWHCD030 FWWHCD050C FWWHCD060C FWWHC100C FWWHCD120C FWWHCD140C FWWHCD200C
Ground/hot source side inlet/outlet:10℃/-, water from 15℃ to 55℃
Heating capactiy① KW 8.3 14.5 17.4 29.0 34.0 40.6 58.0
BTU/h 28300 49500 59400 98900 116000 138500 197900
COP① W/W 4.1 4.1 4.1 4.1 4.1 4.1 4.1
Input power(Heating)① KW 2.02 3.54 4.24 7.07 8.29 9.90 14.15
Input current(Heating)① A 9.2 6.7 8.1 13.4 15.7 18.8 26.9
Ground/hot source side inlet/outlet:10℃/-, water inlet:30℃, water outlet: 35℃
Heating capactiy① KW 9.6 16.0 19.2 32.0 38.4 44.8 64.0
BTU/h 32800 54600 65500 109200 131000 152900 218400
COP① W/W 5.4 5.4 5.4 5.4 5.4 5.4 5.4
Input power(Heating)① KW 1.78 2.96 3.56 5.93 7.11 8.30 11.85
Input current(Heating)① A 8.1 5.6 6.8 11.3 13.5 15.8 22.5
Ground/hot source side inlet/outlet:10℃/-, water inlet:40℃, water outlet: 45℃
Heating capactiy② KW 9.0 15.0 18.0 30.0 36.0 42.0 60.0
BTU/h 30700 51200 61400 102400 122800 143300 204700
COP② W/W 4.05 4.05 4.05 4.05 4.05 4.05 4.05
Input power(Heating)② KW 2.22 3.70 4.44 7.41 8.89 10.37 14.81
Input current(Heating)② A 10.1 7.0 8.4 14.1 16.9 19.7 28.1
Ground/hot source side inlet/outlet::30℃/35℃; water inlet:12℃, water outlet: 7℃
Cooling capacity KW 7.8 13.0 15.6 26.0 31.2 36.4 50.0
BUT/h 26600 44400 53200 88700 106500 124200 170600
Input power(Cooling) KW 1.86 3.08 3.70 6.17 7.32 8.60 11.90
Input current(Cooling) A 8.5 5.8 7.0 11.7 13.9 16.3 22.6
Power supply V/PH/Hz 220/1/50 380/3/50
Compressor Rotary Scroll
Max running current A 14.5 10.1 12.2 20.3 24.3 28.4 40.5
Noise dB(A) 50 50 51 53 55 55 56
Water inlet/outlet inch 1″ 1″ 1″ 1-1/4″ 1-1/4″ 1-1/2″ 2″
Water flow volume(5~3℃difference) m³/h 1.7~2.6 2.8~4.3 3.3~5.2 5.5~8.6 6.6~10.3 7.7~12.0 11.0~17.2
Refrigerant R32/R410A
Model   FWWHCD250C FWWHCD300C FWWHCD360C FWWHCD400C FWWHCD500C FWWHCD600C FWWHCD1000C
Ground/hot source side inlet/outlet:10℃/-, water from 15℃to 55℃
Heating capactiy① KW 72.5 87.0 115.2 116.0 145.0 174.0 290.0
BTU/h 247400 296800 393100 395800 494700 593700 989500
COP① W/W 4.1 4.1 4.1 4.1 4.1 4.1 4.1
Input power(Heating)① KW 17.68 21.22 28.10 28.29 35.37 42.44 70.73
Input current(Heating)① A 33.6 40.3 53.4 53.7 67.2 80.6 134.3
Ground/hot source side inlet/outlet:10℃/-, water inlet:30℃, water outlet: 35℃
Heating capactiy① KW 80.0 96.0 115.2 128.0 168.0 192.0 320.0
BTU/h 273000 327600 393100 436700 573200 655100 1091800
COP① W/W 5.4 5.4 5.4 5.4 5.4 5.4 5.4
Input power(Heating)① KW 14.81 17.78 21.33 23.70 31.11 35.56 59.26
Input current(Heating)① A 28.1 33.8 40.5 45.0 59.1 67.5 112.5
Ground/hot source side inlet/outlet:10℃/-, water inlet:40℃, water outlet: 45℃
Heating capactiy② KW 75.0 90.0 108.0 120.0 150.0 180.0 300.0
BTU/h 255900 307100 368500 409400 511800 614200 1023600
COP② W/W 4.05 4.05 4.05 4.05 4.05 4.05 4.05
Input power(Heating)② KW 18.52 22.22 26.67 29.63 37.04 44.44 74.07
Input current(Heating)② A 35.2 42.2 50.6 56.3 70.3 84.4 140.7
Ground/hot source side inlet/outlet::30℃/35℃; water inlet:12℃, water outlet: 7℃
Cooling capacity KW 65.0 75.0 90.0 100.0 120.0 150.0 250.0
BUT/h 221800 255900 307100 341200 409400 511800 853000
Input power(Cooling) KW 15.29 17.80 21.40 23.80 28.24 35.70 59.50
Input current(Cooling) A 29.0 33.8 40.6 45.2 53.6 67.8 113.0
Power supply V/PH/Hz 380/3/50
Compressor Scroll
Max running current A 50.7 60.8 72.9 81.0 101.3 121.6 202.6
Noise dB(A) 56 57 59 62 62 65 67
Water inlet/outlet inch 3″ 3″ 3″ 4″ 4″ 4″ 5″
Water flow volume(5~3℃difference) m³/h 13.8~21.5 16.5~25.7 19.8~30.9 22.0~34.4 28.9~43.0 33.0~51.6 55.0~86.0
Refrigerant R32/R410A

Contact Us