Applications:
18 years experience – Fantastic company has manufactured over 35,000 water-to-water heat pumps worldwide.
Affordability – Save energy & high performance – As the high COP of Fantastic geothermal heat pump, it can heat the water for about 30% of the cost of heating with gas and 75% of electric water heater, High COP means more energy saving.
Ex. $ 1 input – $ 4.6 of energy output at COP of 4.6.
Long life with famous brand high-quality components – CAREL controller and CAREL expansion valve for option, Copland or Panasonic compressor, SWEP plate heat exchanger, WILO water pump, and so on. All the heat pumps are equipped with famous international brand components, and we also can manufacture the casing with stainless steel, and much experience with titanium heat exchanger heat pumps for someplace where water quality is pool or water requirement is special.
Wide models range – we can design and make from resident to commercial ground source heat pumps up to 350 kW or bigger as your actual pool situation.
The heating capacity of Fantastic water to water heat pump is up to 500kW and larger. Suitable for different sizes of project demands, no matter for household or commercial use. Customized design for different customers’ projects.
Fantastic heat pump has precise energy stage settings to ensure the working unit achieves the desired energy-saving efficiency. The heat pump will change the compressor using quantity according to the real heat required by the water inlet temperature. When it requires a higher heating load, the unit will use full compressor quantity; when the water temperature is close to the target set temperature and requires a lower heating load, the unit will turn off some compressors and just use the compressor quantity according to the real heat load.
The outside of the titanium or copper tube is screw twisted fin tube design, compared with a normal smooth copper tube, greatly increase the heat exchange area between the refrigerant and water, ensure that the refrigerant and water can fully heat exchange. There is no water flow blind zone in the water passage, the water flow velocity is uniform, and the heater is not easy to partially freeze, not easy to scale.
Fantastic water to water heat pump has high energy saving performance, which make COP as high as 5.4.
Fantastic heat pump increases the heating capacity and extends the operating life by TEV, and increases COP and limits the discharge temperature under safe level by EEV, and lower the defrosting time to make heat pump put more time on heating and more energy-saving.
Model | FWWHCD030 | FWWHCD050C | FWWHCD060C | FWWHC100C | FWWHCD120C | FWWHCD140C | FWWHCD200C | |
Ground/hot source side inlet/outlet:10℃/-, water from 15℃ to 55℃ | ||||||||
Heating capactiy① | KW | 8.3 | 14.5 | 17.4 | 29.0 | 34.0 | 40.6 | 58.0 |
BTU/h | 28300 | 49500 | 59400 | 98900 | 116000 | 138500 | 197900 | |
COP① | W/W | 4.1 | 4.1 | 4.1 | 4.1 | 4.1 | 4.1 | 4.1 |
Input power(Heating)① | KW | 2.02 | 3.54 | 4.24 | 7.07 | 8.29 | 9.90 | 14.15 |
Input current(Heating)① | A | 9.2 | 6.7 | 8.1 | 13.4 | 15.7 | 18.8 | 26.9 |
Ground/hot source side inlet/outlet:10℃/-, water inlet:30℃, water outlet: 35℃ | ||||||||
Heating capactiy① | KW | 9.6 | 16.0 | 19.2 | 32.0 | 38.4 | 44.8 | 64.0 |
BTU/h | 32800 | 54600 | 65500 | 109200 | 131000 | 152900 | 218400 | |
COP① | W/W | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 |
Input power(Heating)① | KW | 1.78 | 2.96 | 3.56 | 5.93 | 7.11 | 8.30 | 11.85 |
Input current(Heating)① | A | 8.1 | 5.6 | 6.8 | 11.3 | 13.5 | 15.8 | 22.5 |
Ground/hot source side inlet/outlet:10℃/-, water inlet:40℃, water outlet: 45℃ | ||||||||
Heating capactiy② | KW | 9.0 | 15.0 | 18.0 | 30.0 | 36.0 | 42.0 | 60.0 |
BTU/h | 30700 | 51200 | 61400 | 102400 | 122800 | 143300 | 204700 | |
COP② | W/W | 4.05 | 4.05 | 4.05 | 4.05 | 4.05 | 4.05 | 4.05 |
Input power(Heating)② | KW | 2.22 | 3.70 | 4.44 | 7.41 | 8.89 | 10.37 | 14.81 |
Input current(Heating)② | A | 10.1 | 7.0 | 8.4 | 14.1 | 16.9 | 19.7 | 28.1 |
Ground/hot source side inlet/outlet::30℃/35℃; water inlet:12℃, water outlet: 7℃ | ||||||||
Cooling capacity | KW | 7.8 | 13.0 | 15.6 | 26.0 | 31.2 | 36.4 | 50.0 |
BUT/h | 26600 | 44400 | 53200 | 88700 | 106500 | 124200 | 170600 | |
Input power(Cooling) | KW | 1.86 | 3.08 | 3.70 | 6.17 | 7.32 | 8.60 | 11.90 |
Input current(Cooling) | A | 8.5 | 5.8 | 7.0 | 11.7 | 13.9 | 16.3 | 22.6 |
Power supply | V/PH/Hz | 220/1/50 | 380/3/50 | |||||
Compressor | Rotary | Scroll | ||||||
Max running current | A | 14.5 | 10.1 | 12.2 | 20.3 | 24.3 | 28.4 | 40.5 |
Noise | dB(A) | 50 | 50 | 51 | 53 | 55 | 55 | 56 |
Water inlet/outlet | inch | 1″ | 1″ | 1″ | 1-1/4″ | 1-1/4″ | 1-1/2″ | 2″ |
Water flow volume(5~3℃difference) | m³/h | 1.7~2.6 | 2.8~4.3 | 3.3~5.2 | 5.5~8.6 | 6.6~10.3 | 7.7~12.0 | 11.0~17.2 |
Refrigerant | R32/R410A |
Model | FWWHCD250C | FWWHCD300C | FWWHCD360C | FWWHCD400C | FWWHCD500C | FWWHCD600C | FWWHCD1000C | |
Ground/hot source side inlet/outlet:10℃/-, water from 15℃to 55℃ | ||||||||
Heating capactiy① | KW | 72.5 | 87.0 | 115.2 | 116.0 | 145.0 | 174.0 | 290.0 |
BTU/h | 247400 | 296800 | 393100 | 395800 | 494700 | 593700 | 989500 | |
COP① | W/W | 4.1 | 4.1 | 4.1 | 4.1 | 4.1 | 4.1 | 4.1 |
Input power(Heating)① | KW | 17.68 | 21.22 | 28.10 | 28.29 | 35.37 | 42.44 | 70.73 |
Input current(Heating)① | A | 33.6 | 40.3 | 53.4 | 53.7 | 67.2 | 80.6 | 134.3 |
Ground/hot source side inlet/outlet:10℃/-, water inlet:30℃, water outlet: 35℃ | ||||||||
Heating capactiy① | KW | 80.0 | 96.0 | 115.2 | 128.0 | 168.0 | 192.0 | 320.0 |
BTU/h | 273000 | 327600 | 393100 | 436700 | 573200 | 655100 | 1091800 | |
COP① | W/W | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 |
Input power(Heating)① | KW | 14.81 | 17.78 | 21.33 | 23.70 | 31.11 | 35.56 | 59.26 |
Input current(Heating)① | A | 28.1 | 33.8 | 40.5 | 45.0 | 59.1 | 67.5 | 112.5 |
Ground/hot source side inlet/outlet:10℃/-, water inlet:40℃, water outlet: 45℃ | ||||||||
Heating capactiy② | KW | 75.0 | 90.0 | 108.0 | 120.0 | 150.0 | 180.0 | 300.0 |
BTU/h | 255900 | 307100 | 368500 | 409400 | 511800 | 614200 | 1023600 | |
COP② | W/W | 4.05 | 4.05 | 4.05 | 4.05 | 4.05 | 4.05 | 4.05 |
Input power(Heating)② | KW | 18.52 | 22.22 | 26.67 | 29.63 | 37.04 | 44.44 | 74.07 |
Input current(Heating)② | A | 35.2 | 42.2 | 50.6 | 56.3 | 70.3 | 84.4 | 140.7 |
Ground/hot source side inlet/outlet::30℃/35℃; water inlet:12℃, water outlet: 7℃ | ||||||||
Cooling capacity | KW | 65.0 | 75.0 | 90.0 | 100.0 | 120.0 | 150.0 | 250.0 |
BUT/h | 221800 | 255900 | 307100 | 341200 | 409400 | 511800 | 853000 | |
Input power(Cooling) | KW | 15.29 | 17.80 | 21.40 | 23.80 | 28.24 | 35.70 | 59.50 |
Input current(Cooling) | A | 29.0 | 33.8 | 40.6 | 45.2 | 53.6 | 67.8 | 113.0 |
Power supply | V/PH/Hz | 380/3/50 | ||||||
Compressor | Scroll | |||||||
Max running current | A | 50.7 | 60.8 | 72.9 | 81.0 | 101.3 | 121.6 | 202.6 |
Noise | dB(A) | 56 | 57 | 59 | 62 | 62 | 65 | 67 |
Water inlet/outlet | inch | 3″ | 3″ | 3″ | 4″ | 4″ | 4″ | 5″ |
Water flow volume(5~3℃difference) | m³/h | 13.8~21.5 | 16.5~25.7 | 19.8~30.9 | 22.0~34.4 | 28.9~43.0 | 33.0~51.6 | 55.0~86.0 |
Refrigerant | R32/R410A |